Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0925-00395
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2025 | Commercial Electrical Fast | REQUIRES RESUBMIT | Commercial Electrical Review TS-PRM-0925-00395 (4420 N STONE AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Add the following verbiage to each internally illuminated sing sheets. All Signs and power supply components are UL listed. NEC 600.3. All Signs shall have UL sticker, manufacturer sticker & Installer sticker, located on the exterior of the sign. NEC 600.4. All dedicated sign circuits shall be labeled. NEC 600.5. A safety lockout shall be provided for all signs where the shut off switch is not directly visible to the sign. NEC 600.6. This sign is intended to be installed in accordance with the requirements of Article 600 of the 2017 National Electrical Code and/or other applicable codes. This includes proper grounding and bonding of the sign, Article 600.7 and location of the disconnect switch after the installation shall comply with Article 605(A)(1) of the National Electrical Code. 2. Provide the number of circuits required and the amp rating of each sign. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/25/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TS-PRM-0925-00395 (4420 N STONE AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Outdoor Lighting Review: 1. Add the following notes to each Illuminated Sigh sheet: “As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K, OLC 501.3.2.” “24 hour programmable timer installed to comply with the COT Outdoor Lighting Code. The means of controlling the specific “off” curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “ 2. Provide permanent curfew “off” time sign or notice: Whenever any curfew “off” time is required by this Code, a permanent sign or notice shall be installed at the time control device stating the required turn-off time. Such sign or notice may be installed within the cover of the time control device such that it is visible whenever the device is set or adjusted, OLC 403.5.2. Suggested wording is as follows: “Set off time for Sign no later than 10:00PM MST in accordance with City of Tucson/Pima County Outdoor Lighting Code. Penalty for non-compliance per Outdoor Lighting Code Section 107.4. Penalties shall not exceed $750.00 for individuals and $10,000.00 for other legal entities.” (Adjust wording as needed for type of lighting to which curfew applies and the applicable curfew time.) 3. The addition of the ‘Red Sloan LED’ lights around the parapet of the building requires compliance with the outdoor lighting. See comments below: 1. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your lighting fixture table and use the same number on your site plan. 2. List the Lighting Area per OLC (E3) chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. 3. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation. 4. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. 5. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 6. Fixtures installed under canopies and overhangs. Outdoor lighting fixtures shall not be counted in determining the total light output when they are full cutoff light fixtures installed under canopies, building overhangs, or roof eaves, OLC 401.2.1(3). 7. Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf 8. Specify any exceptions used. 9. Provide Curfew lighting controls If applicable Per section 403. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 10/09/2025 | Signs Standard | REQUIRES RESUBMIT | Sign Review TS-PRM-0925-00395 4420 N. Stone Av. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, and adopted Building Code. Application: 1. This submittal is missing the sign application. Please complete and resubmit with the sign application as the first page in the sign drawings, not as a separate page. Below is a link to the permit application. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/applicationsforms/sign-permit-application_032825.pdf 2. Identity Sign must have a valid City of Tucson business license. The current business license on file is expired. Contact he licensing department at license@tucsonaz.gov or 520-791-4566. Sign Drawings: 1. Each sign must have it's own sign designation (A, B, C, etc...) that must match application and be uniform throughout drawing in alphabetical characters. Include these labels on site plan. 2. All dimensions must be FEET.DECIMAL - not FEET INCHES 3. Provide a call out for what materials the wall is constructed from. 4. Add exact language: All signs and power supply components are UL listed. All signs shall have UL sticker, manufacturer sticker and installer sticker, located on the exterior of the sign for inspections. All dedicated sign circuits shall be labeled. A safety lock out shall be provided for all signs where the shut off switch is not directly visible to the sign. 24 hour programmable timer installed to comply with the COT Outdoor Lighting Code. As per the City of Tucson Outdoor Lighting Code the internally illuminated sign as shown on this page does not exceed the 4400k color temp. 5. Add the number of AMPs this sign will pull when illuminated. |