Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TS-PRM-0925-00380
Parcel: 127122750

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0925-00380
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2025 Commercial Electrical Fast APPROVED
09/15/2025 Outdoor Lighting Standard APPROVED
09/22/2025 Signs Standard REQUIRES RESUBMIT Sign Review TS-PRM-0925-00380 5601 E. Broadway Bl. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Code reference: Unified Development Code, Article 7A: Sign Standards, Outdoor Lighting Code, 2025 adopted Building Codes.

Application:
1) Site is allowed 225 sq ft of sign area. The proposed sq ft is above the allowed and will need to be reduced.

Sign Drawings:
1) AF6-1/4" Toggler Alligator Anchor Bolts are not an adequate method of attachment and will not be able to support the weight of the sign. Please revise with an adequate attachment method.
2) This entire area is considered one sign. Combine Signs C & D into one sign. Dimensions, applications and drawings all need to be updated.
3) Verify actual amperage on all signs with manufacturer as this is pulling the same amperage as the smaller sign.
4) Specify anchor type as noted on the drawings for Sign D.