Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TS-PRM-0924-00432
Parcel: 140260200

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.2

Permit Number - TS-PRM-0924-00432
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2024 Sign Post Review Express PENDING ASSIGNMENT
11/07/2024 Commercial Building REQUIRES RESUBMIT A. My apology, perhaps I wasn't clear on my previous request.
B. The previous request was not satisfied.
C. The Structural Calculation and Drawings are to be done by a Structural Engineer licensed in Arizona (drawings as to be sealed/signed/dated). We thank you for submitting a cross section sketch of the monument sign. However we require more than that one drawing. Allow me to copy and paste the request once again.
ACTIVITY NO. TS-PRM-0924-00432 ADDRESS/PARCEL: (6393 S CAMPBELL AV TUCSON, AZ 85706) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Submit Structural Calculation and detail drawing for the drilled pier/foundation and the steel tube used. 2. Submit detail drawing for the sign box to include the framing used, method of frame connections used, material/sizes used, etc. 3. Submit attachment detail drawings as to how the sign box frame is attached to the steel tube that is embedded with the drilled pier. Identify the locations of these attachments within the drawings. 4. Please resubmit.
10/28/2024 Signs REQUIRES RESUBMIT 1. CORRECT THE ADDRESS ON THE APPLICATION

2. LOCATION MAPS/ AERIAL PHOTOS ARE USED FOR WALL SIGNS, DIRECTIONALS OR CHANGE OF COPY.

WHEN BUILDING A NEW MONUMENT SIGN, YOU MUST USE A SITE PLAN.
YOU HAVE TO USE A COPY OF THE LAST SITE PLAN ON RECORD WITH THE CITY OF TUCSON.

MAKE THE SITE PLAN THE 4TH PAGE OF THIS SIGN PACKAGE. CLEARLY HIGHLIGHT THE PROPERTY LINE. INDICATE THE SETBACK DISTANCE FOR THE PROPERTY LINE + THE SIGN, FROM THE CORNER, VALENCIA, AND CAMPBELL.