Permit Number: TS-PRM-0923-00491
Parcel: 12212015C

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0923-00491
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2023 Signs REQUIRES RESUBMIT RE: LED Illuminated Channel Letter signs
FOR: Take 5 Oil Change
AT: 4501 E Speedway Bl Zoned C-2 (3 to 1 sign ratio)
PERMIT: TS-PRM-0923-00491
DATE: 9/20/2023
REVIEWER: H. Thrall (heather.thrall@tucsonaz.gov) R. Parsons (robert.parsons@tucsonaz.gov)
CODES: Unified Development Code 7A Sign Standards (UDC), National Electrical Code 600 (NEC), Tucson – Pima County Outdoor Lighting Code (OLC), International Building Code 2018 (IBC).
1. UDC:
A. The sign area as indicated by your plans is acceptable.
B. The monument sign may only count towards the Speedway street frontage. To ensure that, take the street curb for Speedway and Belvedere and draw a line where they would theoretically meet. At that point where those street curbs would meet, slice it in half and draw the line into the site. Keep the sign on the Speedway side of that line. The sign can be 20' setback from face of curb to leading edge of the sign. (So move the sign south.)

2. OLC:
A. Please add note stating all illuminated signs will shut off at midnight.

3. NEC:
A. Please label shutoff switch for the monument sign.
B. Add a note dedicated sign circuits will be labeled and shown at inspection.
C. Add a note UL sticker, manufacturer sticker, installer sticker will be placed on all signs.
D. Please provide a safety lockout box for all illuminated wall signs, label on all plan sheets.
E. Please update plans to show the volts/circuits for each sign in the package.


3. IBC:
A. The monument footer should have 6” gravel noted at bottom of footer below pipe.
B. Please provide details on how the cabinet will be mounted to the pole inside
the monument sign.
C. Clarify if multiple cabinets, and if so, how will they be mounted to the pole and connected to each other?
D. Clarify if base is masonry or metal skirt and how it will be mounted.
Depending on revisions submitted, further review comments may be forthcoming.