Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0825-00332
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2025 | Commercial Building Standard | APPROVED | |||
| 08/06/2025 | Commercial Electrical Fast | REQUIRES RESUBMIT | Commercial Electrical Review TS-PRM-0825-00332 (4525 N ORACLE RD TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Add the following verbiage to each internally illuminated sing sheets. All Signs and power supply components are UL listed. NEC 600.3. All Signs shall have UL sticker, manufacturer sticker & Installer sticker, located on the exterior of the sign. NEC 600.4. All dedicated sign circuits shall be labeled. NEC 600.5. A safety lockout shall be provided for all signs where the shut off switch is not directly visible to the sign. NEC 600.6. This sign is intended to be installed in accordance with the requirements of Article 600 of the 2017 National Electrical Code and/or other applicable codes. This includes proper grounding and bonding of the sign, Article 600.7 and location of the disconnect switch after the installation shall comply with Article 6005(A)(1) of the National Electrical Code. 2. Provide the number of circuits required and the amp rating of each sign. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/06/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TS-PRM-0825-00332 (4525 N ORACLE RD TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Code: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf 1. Add the following verbiage to each internally illuminated sing sheets. As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K. 24 hour programmable timer installed to comply with the COT Outdoor Lighting Code The means of controlling the specific “off” curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. Timer/curfew notice per OLC 403.5.2. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/08/2025 | Signs Standard | REQUIRES RESUBMIT | Application: 1) Change of Copy permits under 35 sq ft do not require permit. Remove Sign A from permit package. Sign Drawings: 1) Sign Designation must match application and be uniform throughout drawing in alphabetical characters. 2) Specify what materials the wall is made from. I.E. Masonry, Wood with stucco, etc... Site Plan: 1) Site plans need to show placement of signs on buildings and/or where freestanding signs are placed. |