Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0824-00353
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/23/2024 | Commercial Building | APPROVED | |||
08/26/2024 | Sign Post Review | PENDING ASSIGNMENT | |||
08/26/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1Provide complete compliance with the 2012 City of Tucson Outdoor Lighting Code. See Chapter 5 for specific Sign requirements, and the external illumination shall conform to all the requirements of the Code. 2 Provide complete sealed electrical plans for the exterior luminaires (installed by electrical contractor) providing the uplighting, design and calculations performed by an Arizona Registrant. Ref; 2018 IBC section 107.2.1, 2017 NEC, 2012 City of Tucson Outdoor Lighting Code, City of Tucson Commercial Plan Submittal Requirements. |
||
08/26/2024 | Signs | REQUIRES RESUBMIT | RE: Install freestanding sign with spotlighting FOR: Lynx Mini Yards AT: 9683 E Rita Commerce Dr. Tucson, AZ 85747; Zoned I-1 (4 to 1 sign ratio) PERMIT: TS-PRM-0824-00353 DATE: 8/26/2024 REVIEWER: R. Parsons (robert.parsons@tucsonaz.gov) CODES: Unified Development Code 7A Sign Standards (UDC), National Electrical Code 600 (NEC), Tucson – Pima County Outdoor Lighting Code (OLC), International Building Code 2018 (IBC). 1. UDC: A. Per UDC 7A.10.2.A Table 1, your proposed sign is classified as a monument sign (post/panel) and is permittable in the I zone. The proposed sign area of 49.79 is acceptable. Thank you. B. Please include a City of Tucson sign application on your next submittal. The sign permit application can be found here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Sign-Permits#section-2. Please make sure the document is filled out completely. C. Per UDC 7A.10.2.C.2.a, the minimum setback for a monument sign is 20’ from front of curb to leading edge of sign. Please update your sign location to ensure this setback is met from all sides. Currently, your plans show the sign only 5.5’ from back of curb. 3. NEC/OLC: A. Per City of Tucson outdoor lighting code Section 501.1 “External illumination for on-site signs shall conform to all provisions of this code. In particular, such lighting shall conform to the lamp source, shielding requirements, color temperature, and lumen caps of Chapter 4”. It might be advantageous for you to figure out a way to make the illumination come from the top of the cabinet. 4. IBC: A. Per communication with our commercial building reviewer, please clearly label how the “post” will be mounted to the "square tube" and how the “square tube” will be mounted to the “cabinet”. Depending on revisions submitted, further review comments may be forthcoming. I can be reached at Robert.Parsons@tucsonaz.gov if you have additional questions. |