Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0824-00340
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2024 | Sign Post Review Express | PENDING ASSIGNMENT | |||
| 08/16/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TS-PRM-0824-00340 ADDRESS/PARCEL: (4646 N ORACLE RD TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. SIGN A: Please provide drawing detail of the monument sign’s Block Base. Provide detail drawing as to how the sign is attached to this Block Base, make sure to specify the type of attachment/anchors used. Please also provide detail drawing as to how the sign is attached to the 5 inch steel pipe, show where they are and how often they occur, make sure to specify the type of attachment/anchors used. Please have the same structural engineer used in item #2 below generate this drawing/calculation with his/her seal/signature/date on them. 2. SIGN B, D, G, H, I, J: Please provide Structural drawings and calculations on these wall signs that are sealed/signed/dated. Ideally, when calculating the lateral forces.. please use 115 mph 3 second gust of wind. make sure to specify the type of attachment/anchors used and their embedment depths. Do make sure to show/indicate the wall materials these signs are being attached to. 3. Please resubmit. |
||
| 08/16/2024 | Signs | REQUIRES RESUBMIT | RE: Install 1 lighted monument sign, 10 lighted wall signs, 5 lighted directional signs and 3 canopy signs. FOR: Mister Car Wash AT: 4646 N Oracle Rd Tucson, AZ 85705; Zoned C-3 (3 to 1 sign ratio) PERMIT: TS-PRM-0824-00340 DATE: 8/16/2024 DUE DATE: 8/16/2024 REVIEWER: R. Parsons (Robert.Parsons@tucsonaz.gov) CODES: Unified Development Code 7A Sign Standards (UDC), National Electrical Code 600 (NEC), Tucson – Pima County Outdoor Lighting Code (OLC), International Building Code 2018 (IBC). 1. UDC: A. TD-DEV-1223-00492 is still in review and has not yet been approved for this site. Please resubmit your sign package once the development package has been approved. Depending on revisions submitted, further review comments may be forthcoming. I can be reached at Robert.Parsons@tucsonaz.gov if you have additional questions |