Permit Number: TS-PRM-0726-00279
Parcel: 13315299A

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.2

Permit Number - TS-PRM-0726-00279
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/03/2026 Commercial Building Standard APPROVED
09/24/2026 Sign Post Review Express PENDING ASSIGNMENT
09/01/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review: TS-PRM-0726-00279 (6910 E TANQUE VERDE RD TUCSON, AZ 85715)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Outdoor Lighting Review:

>>> The following comments were not addressed:

1. Add the following notes to each Internally Illuminated Sigh sheet:



“As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K, OLC 501.3.2.”



“24-hour programmable timer installed to comply with the COT Outdoor Lighting Code.

The means of controlling the specific “off” curfew shall be by a 24-hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “



Provide permanent curfew “off” time sign or notice:

Whenever any curfew “off” time is required by this Code, a permanent sign or notice shall be installed at the time control device stating the required turn-off time. Such sign or notice may be installed within the cover of the time control device such that it is visible whenever the device is set or adjusted, OLC 403.5.2.



Suggested wording is as follows: “Set off time for Sign no later than 10:00PM MST in accordance with City of Tucson/Pima County Outdoor Lighting Code. Penalty for non-compliance per Outdoor Lighting Code Section 107.4. Penalties shall not exceed $750.00 for individuals and $10,000.00 for other legal entities.” (Adjust wording as needed for type of lighting to which curfew applies and the applicable curfew time.)
09/24/2026 Signs Standard REQUIRES RESUBMIT 09/24/2026 Review Comments:
Sign Review TS-PRM-0726-00279 6910 E. Tanque Verde Rd. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049.
The previous review comments were not addressed in the latest submittal. In the next submittal, please submit a correction letter stating how these corrections have been addressed.

1) Please call out the total street frontage length on the site plan so that we can determine what total allowed square footage for the site would be.
2) All dimensions must be in Feet.decimal format not feet and/or inches. For instance, 5’3” = 5.25’. 
3) Setback of freestanding sign off of N Indian Ruins Rd needs to be 20' from curb to leading edge of sign. The dimension shown on the site plan is not showing from the leading edge of the curb to the closest edge of the sign. It is showing to the furthest edge of the sign and the 17.17’ dimension is showing to the middle of the sign. 7a.10.2.C.2.A.1.I.D
4) Sight Visibility Triangles are not properly displayed on the site plan. Please review section 10-01.5.0 of the Unified Development Code on the requirements for Sight Visibility Triangles and revise site plan to show correct SVTs.
5) Contractor of Record’s name and contact information must be listed on all pages of the drawings and location map/site plan.