Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0725-00321
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2025 | Commercial Building Standard | APPROVED | |||
| 08/01/2025 | Commercial Electrical Fast | APPROVED | |||
| 08/01/2025 | Outdoor Lighting Standard | APPROVED | |||
| 08/04/2025 | Signs Standard | REQUIRES RESUBMIT | Application: 1) We can not approve this permit until the building permits TC-COM-0125-00047 & TC-COM-0125-00049, TC-COM-1224-02368 are paid for and issued. Resubmit once the building permit is paid for and issued. Sign Drawings: 1) All LED EMC drawings : No animation or scrolling allowed. Image must stay on screen for at least One (1) minute before changing As per the City of Tucson Outdoor Lighting Code the Electronic Message Center As shown on this page automatically Dims to 200 NITS or less from sunset to sunrise. The EMC can not interfere with FCC communications. We need the manufacture of the EMC to sit down and write a letter to The City of Tucson That says the following... #1. name of the manufacturer. #2. the EMC model number/name #3. - This model is fully capable of lowering to 200 nits at night. #4. This model is FCC compliant. 2) Sign E- This entire area is considered one sign. Per Sign Standards 7A.10.2.C.3.d.3, no more than 40% of the wall area can be occupied by signage. These signs occupy more than 40%. Please revise to conform to standards or apply for a Master Sign Plan for all signage. 3) Sign C- OAH should be from ground to top of sign. Revise dimension to include top cap. Indicate location of electrical disconnect switch. Add the number of AMPs this sign will pull when illuminated. 4) Sign B- Indicate location of the electrical disconnect switch. OAH should be from ground to top of sign. Revise dimension to include top cap. 5) Sign A- Per Sign Standard 7A.10.2.C.2.b., OAH for a freeway sign is 48' from freeway grade to top of sign. Please indicate where freeway grade is on height of sign. Indicate location of the electrical disconnect switch. Please indicate the dimension of the pole cover that conforms to Sign Standards, 7A.10.2.C.2.a.3.iv.b.iii. Site Plan: 1) Add line indicating frontage length along the Freeway and Congress St. 2) Per Sign Standard 7A.10.2.C.2.a.2, this site is allowed one freestanding sign per street frontage. There are three freestanding signs being propopsed. This is only permitted on sites that have 450 feet of street frontage or more on one street frontage. Reduce the number of freestanding signs or apply for a Master Sign Program for all signage on site. 3) Per Sign Standards 7A.10.2.C.1.a.2, Directional signs cannot be located in the SVT. Minimum setback is 10' from the face of curb. 4) Label all Sight Visibility Triangle dimensions per UDC code 10-01.5. 5) Per Sign Standard 7A.10.2.C.2.a, Minimum setback for monument signs is 20' from the face of curb and pole signs is 30' from face of curb. Please show distance of setback from face of curb for all freestanding signs. |