Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0723-00429
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/31/2023 | Signs | REQUIRES RESUBMIT | RE: wall sign review (new construction) For: Black Rock Coffee AT: 2402 N 1st Av Permit: TS-PRM-0723-00429 Date: review, 7/31/23) Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov ) Codes: Unified Development Code (7A) Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1. UDC: (Thank you for property management approval letter!) A) These plans cannot be resubmitted until such time as the development package and building plans have each been APPROVED. Both are still in early stages of review. B) Staff conducted this review in anticipation that the site review aspects will be processed within the next few weeks, that no significant site changes will result in a change of sign area that would be allowed, and to provide courtesy feedback to assist with moving forward to order signage. C) I acknowledge the proposed wall signs and the actual proposed sign area in total and for each sign and elevation will be within code allowances, given the type of development for the planned location, with building and drive thru lane service. D) add the lot line dimensions off 1st Avenue to the location plan. E) add the lot line dimension off Grant Road to the location plan. F) Once the development plan and building plan are approved, please include a copy of the site plan sheet with lot line dimensions and a copy of the building plan elevations with dimension in the resubmittal of this package. You can monitor for approval on our PRO site for the development plan at this link: https://pro.tucsonaz.gov/permitdetails/TD-DEV-0423-00210/ You can monitor for approval on our PRO site for the building plan at this link: https://pro.tucsonaz.gov/permitdetails/TC-COM-0423-01139/ **Before you resubmit, please address the following on the plans for the permit record:** 2. NEC: A) add note to each sheet of the plan set: “all signs shall be UL or MET listed” B) add note to each sheet of the plan set: “all signs shall have UL sticker, manufacturer’s sticker, installer sticker on each sign” C) add note to each sheet of the plan set: “safety lock outs shall be provided to all signs where disconnect is not immediately visible to the sign.” D) add note to each sheet of the plan set: “dedicated sign circuit to be provided and labeled at the breaker panel” 3. OLC: A) add note to each sheet of the plan set: “all signs shall turn off at midnight via the provided timer” 4. IBC: A) please add the typical number of each lag shield used per sign / letter / logo on the typical diagrams 5.) General – if you wish to include menu stations here, they do not count toward allowed sign area – and, you’ll need to know this in advance and add them to the sign permit package, as only the electrical to power these signs are looked on building plans: A) minimum setback from drive thru face of curb to the leading edge of any sign supports / cabinets B) show location of disconnect switches C) show all construction assembly / footers / electrical (volts, amps, circuits) D) for digital signs, add a note what manufacturer, that they can dim to 200 Nits from sunset to midnight via photocell / timer, and no animations, and will be FCC compliant – and list manufacturer / unit E) show any clearance bars and footers F) show any traffic directional signs and their construction specs / illumination Depending on revisions resubmitted, further review comments may be forthcoming. I may be reached at Heather.Thrall@tucsonaz.gov if you have any questions. Thank you. |