Permit Number: TS-PRM-0623-00375
Parcel: 130090670

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.2

Permit Number - TS-PRM-0623-00375
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/07/2023 Signs REQUIRES RESUBMIT RE: Illuminated Wall Sign
For: Rodeo Dental & Orthodontics
AT: 3346 S 6th Ave Unit 192 Tucson, AZ 85713 Zoned C-2 (3 to 1 ratio sign area)
Permit: TS-PRM-0623-00375
Date: 7/7/2023 (2nd Review)
Reviewer: R. Parsons (Robert.Parsons@tucsonaz.gov)
Codes: Unified Development Code (7A) Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018
1. UDC:
A. The sign area is allowed as proposed.
2. NEC: A. Please add weep holes to all signage.
B. Provide the following standard notes:
1. All signs shall have a UL, a manufacturer, and installer stickers on the signs.
2. A dedicated sign circuit shall be provided and shall be labeled for inspections.
3. OLC: A. Your data layer needs to be clear so that the sign is no greater than 4,400K.
4. IBC: A. The lag bolts proposed are acceptable for mounting all forms of the signage to any type of wall. Please provide typical number of attachments for each mount.
B. Specify how the letters will be mounted to the raceway.

Your sign will qualify for a self-certification inspection once permitted.
Depending on revisions resubmitted, further review comments may be forthcoming.
I may be reached at Robert.Parsons@tucsonaz.gov if you have any questions.