Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0526-00162
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2026 | Outdoor Lighting Standard | APPROVED | |||
| 05/19/2026 | Commercial Electrical Fast | REQUIRES RESUBMIT | Electrical Review: TS-PRM-0526-00162 (4951 S CAMPBELL AV TUCSON, AZ 85706) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Add the following verbiage to each internally illuminated sing sheets. All Signs and power supply components are UL listed. NEC 600.3. All Signs shall have UL sticker, manufacturer sticker & Installer sticker, located on the exterior of the sign. NEC 600.4. All dedicated sign circuits shall be labeled. NEC 600.5. A safety lockout shall be provided for all signs where the shut off switch is not directly visible to the sign. NEC 600.6. This sign is intended to be installed in accordance with the requirements of Article 600 of the 2017 National Electrical Code and/or other applicable codes. This includes proper grounding and bonding of the sign, Article 600.7, and location of the disconnect switch after the installation shall comply with Article 605(A)(1) of the National Electrical Code. |
||
| 05/29/2026 | Signs Standard | REQUIRES RESUBMIT | 05/29/2026 Review Comments: Sign Review TS-PRM-0526-00162 4951 S. Campbell Av. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049. 1. Provide the materials the wall is constructed of so attachment detail can be determined to be sufficient. 2. Provide dimension of wall facing adjacent roadway (Campbell). This is the dimension that will be used to calculate allowed square footage. |