Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.4
Permit Number - TS-PRM-0525-00227
Review Name: PERMANENT SIGN REVIEW v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/30/2025 | Commercial Building Standard | APPROVED | |||
| 07/18/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TS-PRM-0525-00227 (355 N WILMOT RD TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide disconnect per NEC art; 600.6. Where the disconnecting means is out of the line of sight from any section that is able to be energized, the disconnecting means shall be lockable in accordance with 110.25 2. Show all wiring methods in detail for all new branch circuit wiring and feeders. Conductor size/type and conduit size/type. Note wet use requirements. NEC arts; 600.5(D), 300 and 408.4. 3. Provide/note sign grounding and bonding per NEC art; 600.7. 4. Show or notate a dedicated sign circuit per NEC art 600.5. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov | ||
| 07/18/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TS-PRM-0525-00227 (355 N WILMOT RD TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf 1. Provide Sign Lighting Curfew Controls Per OLC section 501.6 &403.4 and note the curfew per Table 501.5. 2. Notate on the plans that all internally illuminated signs shall have a maximum color temperature of 4400K, per OLC 501.3.2. REF Sheet 3, Specification note #2. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov | ||
| 07/18/2025 | Signs Standard | REQUIRES RESUBMIT | Application: 1) Fill in Frontage, zoning and electrical circuit information on the application. Sign Drawings: 1) Sign Contractor Information (Signs of the Times) needs to be added to each page of the sign package. 2) All dimensions must be Feet,Decimal- not Feet/inches. 3) Revisions letter references electrical plan notes, but there are no electrical plans attached to this submittal. Electrical detail is required showing the electrical illumination details and power disconnect switch. 4) Add exact copy to drawings: No-onsite welding to be performed. As per the City of Tucson Outdoor Lighting Code, the internally illuminated sign as shown on this page does not exceed the 4400K color temp. 24 hour programmable time installed to comply with the COT Outdoor Lighting Code All signs and power supply components are UL listed. All signs shall have UL sticker, manufacturer sticker and installer sticker, located on the exterior of the sign for inspections. All dedicated sign circuits shall be labeled. A safety lock out shall be provided for all signs where the shut off switch is not directly visible to the sign. |
||
| 07/14/2025 | Signs Application Completeness Express | REVIEW COMPLETED |