Permit Number: TS-PRM-0525-00225
Parcel: 12714003C

Address:
355 N WILMOT RD

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0525-00225
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/13/2025 Commercial Building Standard REQUIRES RESUBMIT ACTIVITY NO. TS-PRM-0525-00225
ADDRESS/PARCEL: (355 N WILMOT RD TUCSON, AZ 85711)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval.

COMMENTS:
1. These signs are over 60 ft in the air on the building façade.
a. Please provide a structural calculation and detail drawings done by a Structural Engineer licensed in the State of Arizona.
i. Please identify the wall that the sign is being mounted to such as masonry wall, stud wall with stucco, concrete, etc.
ii. Provide uplift calculation to resist lateral forces such as the wind.
iii. Please use 115 mph at 3 second gust of wind.
iv. Within the detail drawings, specify the fasteners used, their length, their embedment depth and how often does it occur.
v. Please have the engineer seal/sign/date all structural documents.
2. Please resubmit.
If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976
05/27/2025 Commercial Electrical Fast REQUIRES RESUBMIT Commercial Electrical Review TS-PRM-0525-00225 (355 N WILMOT RD TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).


1. Provide disconnect per NEC art; 600.6. Where the disconnecting means is out of the line of sight from any section that is able to be energized, the disconnecting means shall be lockable in accordance with 110.25
05/27/2025 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review TS-PRM-0525-00225 (355 N WILMOT RD TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

Outdoor Lighting Review:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

1. Provide Sign Lighting Curfew Controls Per OLC section 501.6 &403.4 and note the curfew per Table 501.5.
2. Notate on the plans that all internally illuminated signs shall have a maximum color temperature of 4400K, per OLC 501.3.2


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
06/25/2025 Signs Standard REQUIRES RESUBMIT FROM: Georgia Pennington, Lead Planner
DATE: 6/25/25

COMMENTS:

1. Indicate what specific type of walls, instead of just "wall".

2. The square footage for the sign area of Signs A and B do not appear to be correct. Please verify and make sure the drawings and application match.

If you have questions about this transmittal, please contact me at georgia.pennington@hotmail.com