Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TS-PRM-0523-00303
Parcel: 10604005F

Address:
3535 N 1ST AV

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.2

Permit Number - TS-PRM-0523-00303
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2023 Signs REQUIRES RESUBMIT RE: two monument signs proposed
For: Greenwater Apartments
AT: 3535 N 1st Avenue
Sign Permit: TS-PRM-0523-00303
Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov)
Date: 8/1/23

Codes: Unified Development Code, 7A, Sign Standards, National Electrical Code (NEC) 600, Tucson - Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018.

1. UDC 7A. 10.2.B. Chart:
A) The location is a multi-family residential apartment complex, which is permitted to have up to 50 square feet of sign area. The application presents two freestanding signs to be installed at the entry feature off of 1st Avenue. Both signs together present a cumulative sign area of 64 square feet. In addition, two monument signs are present at the location; one at Yavapai and 1st and one at Prince / 1st.

B) Please revise the application to indicate the maximum total cumulative sign area of 50 square feet for direct permit process. Please note that the removal of the existing sign paneling from the structures at the street corners. Addresses may be installed on the structures.

C) Should your client desire to proceed to a master sign program request to exceed 50 square feet total sign area, the signs would need to be designed in a manner that has a base and a top embellishment, which can certainly be done utilizing architectural characteristics of the complex with the stucco / masonry affiliated also on the walls of the sign supports.

D) I acknowledge that the sign locations meet code, as do their height and sign type. Should you resubmit with either both signs at 25 square feet or one at 32 and the other at 18, the proposal would be approved (providing panel removal is noted for the other signs on the street corner locations).

2) NEC - no comments, thank you

3) OLC - no comments, thank you

4) IBC - no comments, thank you

Please email me at Heather.Thrall@tucsonaz.gov if you have any questions.