Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0426-00120
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/10/2026 | Commercial Electrical Fast | APPROVED | |||
| 04/10/2026 | Outdoor Lighting Standard | APPROVED | |||
| 05/01/2026 | Signs Standard | REQUIRES RESUBMIT | 05-01-2026 Review Comments: Sign Review TS-PRM-0426-00120 5775 E. Broadway Bl. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049. 1. The detail on the lag bolt is unclear. Please specific the size and number and whether the bolt will be penetrating into solid wood, or just the plywood. Attachment must meet the requirement of the 2018 IBC 3107.1 Signs and Chapter 1603.1.4. The primary requirements for such signs will be related to structural stability as addressed in Chapter 16 and IBC Appendix H. 2. Please show a dimensional line on the site plan for how the frontager is being calculated. 3. Please add the following required exact copy to the sign drawings: All signs and power supply components are UL listed. All signs shall have UL sticker, manufacturer sticker and installer sticker, located on the exterior of the sign for inspections. 4. Please note that refacing of existing signs under 35 square feet do not require a permit. Please remove Sign B from package unless sign cabinet is being altered in any way other than sliding a panel out and sliding a new one back in. Painting of sign does not require a permit. |