Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0324-00131
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/12/2024 | Sign Post Review | PENDING ASSIGNMENT | |||
04/10/2024 | Commercial Building | REQUIRES RESUBMIT | Starbucks - engineered order station ACTIVITY NO. TS-PRM-0324-00131 ADDRESS/PARCEL: (6291 E SPEEDWAY BL TUCSON, AZ 85712) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Submit Structural drawings and calculations for all Menu Boards and the Clearance Bar (please do make sure to provide connection drawing detail at the intersection of the top horizontal bar and the steel tube post for the clearance bar). 2. Please resubmit. |
||
04/12/2024 | Signs | REQUIRES RESUBMIT | RE: sign review For: Starbucks – drive thru sign relocations AT: 6291 E Speedway Blvd Sign Permit: TS-PRM-0324-00131 Reviewer: Heather Thrall (Heather.Thrall@tucsonaz.gov) Date: 4/12/24 Codes: Unified Development Code (UDC, 7A, Sign Standards), National Electrical Code (NEC), Tucson - Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 1. UDC: A) Understood the proposal entails relocation of some of the Starbucks drive thru signs and install of new. All are reviewed as new for technical code purposes. B) I acknowledge sign sizes and heights proposed are within code allowances, thank you. C) (UDC 7.4.6.5. and general safety per TFD): label that detached signs will be 1 foot minimum from face of drive thru curb to leading closest edge of a sign structure support, 2’ from any driveway, 18” from any parking space, and 5’ from any fire hydrant 2. NEC/ OLC: A) provide volts, amps, circuits, shut off switch shown on each sign type construction sheet B) add standard notes: max color temperature is 4400k C) add notation that use existing timer and signs shall shut off at midnight D) add note that all dedicated sign circuits still provided and all sign circuit breakers labeled at power panel E) add note that all signs shall have UL / MET stickers and manufacturer and installer stickers displayed F) add notes on applicable sheets that the unit is static display, not digital 3. IBC: A) engineered plans and diagrams are needed for the break away bar and menu station B) check all notes on the concrete psi – suggesting less than standard 2500 ? 4) Please clarify if your agency is also relocating the digital menu and canopy station ? If so, please provide all standard notations and engineered plans for that sign as well. And any digital signage has to be hard wired to ethernet (note) or has to be FCC compliant to ensure that it is not interrupting cellular service. I understand timing is essential for projects of this nature. Please email me when you have resubmitted and we will add this resubmittal review to our queues for a faster turn around time. Please feel free to email me with any questions. Thank you! (Heather.Thrall@tucsonaz.gov) |