Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0324-00114
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/12/2024 | Signs | REQUIRES RESUBMIT | RE: freestanding sign review For: Faith Community Church – LED monument sign AT: 8455 E Golf Links Rd (formerly addressed 8325 E Golf Links) Sign permit: TS-PRM-0324-00114 Reviewer: Heather Thrall (Heather.Thrall@tucsonaz.gov) Date: 4/12/24 Codes: Unified Development Code (UDC, 7A, Sign Standards), National Electrical Code (NEC), Tucson - Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 1. UDC: A) Sign allowances, sign height, sign area and sign setbacks – and sight visibility triangles – are all within code, thank you. B) The proposed replacement monument sign is shown in city right of way along Golf Links Road. This review is the referral for the Temporary Revocable Easement (TRE) process to begin with the Department of Transportation’s Real Estate Division. Please contact: Bob.Beecher@tucsonaz.gov to begin the TRE process. C) The church site consists of two parcels owned by the church. The new monument is to be positioned south of west parcel, in right of way, with electrical coming from west parcel near driveway entry. The sign install is considered an on-site sign for sign review purposes. (Existing powered sign last had a permit review under the address 8325 E Golf Links, for a change copy under permit T13OT00338) Check on any existing sign easement on west parcel for the electrical stub out position and provide copy for this permit record if available. Note and advise your clients, please – if no easement exists on this west parcel (along driveway and north of the proposed sign location in right of way), in the event this subject lot is sold, the sign investment would need to be secured as legal as an on-site sign tied to the church property. 2) NEC / OLC (on return from TRE process) A) Add note that power extension to new monument sign is from the prior sign location, but power extension to be run by others via building permit. B) Add label clearly calling out the shut off switch location(s) for the monument sign C) I acknowledge the OLC / FCC and NEC all within code, thank you. 3) IBC: A) add notes how pipe system is mounted to cabinet (i.e. size / typical number of saddle plates / bolts, and bolt size) 4) General note: A) add note that 5’ clearance required around any fire hydrants for sign structures Please feel free to email me with any questions. Thank you! (Heather.Thrall@tucsonaz.gov) |