Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0226-00055
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/17/2026 | Commercial Electrical Fast | APPROVED | |||
| 02/17/2026 | Outdoor Lighting Standard | APPROVED | |||
| 03/09/2026 | Signs Standard | REQUIRES RESUBMIT | Sign Review TS-PRM-0226-000055 4631 N. Oracle Rd. #155. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049. 1) Please provide the type of construction materials the wall is made of. 2) This tenant space is allowed 3 sq ft per lf of tenant space frontage. The frontage provided is 30 lf. 30 x 3 = 90 sq ft of allowed signage. The proposed signage is 95 sq ft, which is outside of compliance with allowed square footage. Please reduce signage to meet code allowances. 3) Provide amount of AMPs each sign will pull when illuminated. |