Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0226-00042
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/10/2026 | Commercial Electrical Standard | APPROVED | |||
| 02/10/2026 | Outdoor Lighting Standard | APPROVED | |||
| 03/06/2026 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TS-PRM-0226-00042 ADDRESS/PARCEL: (4362 N ORACLE RD TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: 1. NEW STEEL BEAM a. Please provide detail drawing on the new top horizontal steel beam. Include the following: b. Indicate what the steel beam is connected to. c. Illustrate how the existing vertical support is supported. i. What is supporting the vertical member. ii. What fastener is used to connect the vertical member to its supporting structure. d. Size and gauge of the new steel beam. e. Length of steel beam. f. Type of fasteners used. i. If welding is used, specify it. 2. ALUMINUM PLATE a. Provide detail drawings. i. What is the required overlap dimension with the new horizontal steel beam. ii. What is the required overlap dimension with the existing side vertical steel members. iii. What is the required overlap dimension with the existing horizontal steel beam. iv. How is this plate fastened to the steel members. 1. If welding is used, please specify on your detail drawing. 3. CHANNEL LETTERS a. What fasteners used to attached the letters to the aluminum plate. i. Please provide detail drawing illustrating this. ii. How often do these fastener occur. iii. Show on your drawing their location. 4. Please resubmit. |
||
| 02/27/2026 | Signs Standard | REQUIRES RESUBMIT | Sign Review TS-PRM-. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049. 1) There are unit numbers assigned to this address. Please verify with Pima County Addressing which unit number is assigned to this tenant. Once this information has been verified, update the plans and the TDC online application through a sub-record request. Once the address has been updated, you can resubmit for review. 2) All dimensions must be in feet.decimal, not feet or inches. 3) Welding on site that is called out on sign A, requires a Special Inspection form and sealed engineering. Please resubmit with both. 4) Show overall height from grade to top of sign. 5) Change of copy under 35 sq ft do not require permit. Remove from sign package. |