Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.2
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2025 Special Inspection Certificate Review (Deferred Submittal) Express REVIEW COMPLETED CONDITION: this is being marked review complete with the understanding that any future submitted field report shall be complete to include information on the required steel angle bracket, type of anchoring used, the number of anchoring used for each letter and confirmation nuts/bolts are all verified installed at the correct tension.