Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.2
Permit Number - TS-PRM-0225-00058
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2025 | Outdoor Lighting Standard | APPROVED | |||
| 07/22/2025 | Signs Standard | APPROVED | |||
| 07/22/2025 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TS-PRM-0225-00058 ADDRESS/PARCEL: (10350 E DREXEL RD TUCSON, AZ 85747) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. Sheet 5 of 8 Engineering (monument sign section) a. From Sheet 3 of 8, the wall that the sign cabinet is attached to is a stucco wall. b. Please provide specific information on this wall. If it is cmu with stucco finish, please add this information onto the engineering drawings. Provide drawings as to how this stucco wall is attached to the base cap. c. Please specify if the stucco cmu wall is to be fully grouted. i. Sheet 3 of 8 indicates #10 x 2” screw is being used to secure the sign cabinet. Please verify that the proper attachment hardware is chosen for a cmu material. ii. What is the base cap made of that the stucco cmu wall is sitting on. d. Nowhere within this submittal provides specific information on the steel tube. i. Please provide the diameter and wall thickness. ii. Provide detail drawings as to how this steel tube is attached to the stucco wall. iii. Provide the embedment depth of the steel tube into the base. The engineering drawing seems to indicate that the base has an empty cavity below the base cap. Please provide drawings illustrating how the steel pipe is being secured below the base cap. 2. Please verify the address. The sign is located at a different address compared to the building permit address. Please correct this discrepancy. Please note that a sign cannot be installed on another address different from the actual location of the facility being advertised. A legal document/agreement may have to be executed and recorded to allow this to occur. 3. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 07/10/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TS-PRM-0225-00058 (10350 E DREXEL RD TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This parcel that the sign is on is not the same as the address used on the permit. The location of the sign does not have an existing building and no records of existing electrical service to the parcel. 141019200 10310 E DREXEL RD 2. Show all wiring methods in detail for all new branch circuit wiring to the new monument sign. Show basic electrical route from service panel to the sign. Conductor size/type and conduit size/type. Note wet use requirements. NEC arts; 600.5(D), 300 and 408.4. 3. Electrical service cannot be located on a separate parcel. How is power getting to this sign? Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |