Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.3
Permit Number - TS-PRM-0224-00059
Review Name: PERMANENT SIGN REVIEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2024 | Sign Post Review Express | PENDING ASSIGNMENT | |||
| 04/30/2024 | Commercial Building | REQUIRES RESUBMIT | Engineered sign package: ACTIVITY NO. TS-PRM-0224-00059 ADDRESS/PARCEL: (8690 E GOLF LINKS RD TUCSON, AZ 85730) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Monument Sign: Provide a structural calculation on the lateral forces that will be affecting this monument sign. 2. Provide structural drawing detail required to resist the forces requested in above item #1. Specify the diameter of the steel pipe that is embedded in the concrete drilled pier all the way to the top of the cabinet sign. These detail drawings are from the bottom (provide structural connection detail drawing in securing the bottom enclosure to the steel pipe), in the middle/LED display (connection detail drawing securing it to the steel pipe), top cabinet (connection detail drawing securing the top of the cabinet to the steel pipe). 3. Please resubmit. |
||
| 04/30/2024 | Signs | REQUIRES RESUBMIT | RE: sign review (detached and wall signs) For: Super Star Car Wash AT: 8690 E Golf Links Rd Sign permit: TS-PRM-0224-00059 Reviewer: Heather.Thrall@tucsonaz.gov Date: 4/30/24 Status: Zoning / Sign Standards approval, pending structural engineering review and approval Codes: Unified Development Code (7A Sign Standards), National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1. UDC: signs will be within code allowances and rezoning conditions for signs are noted now on the plans, thank you - adjust the following for the permit record: A) per prior two reviews: fix the sign area on the freestanding sign to show the actual exterior measured cabinet dimensions (not the visual opening) and adjust it on the plan set and on the application. 2. NEC: no comments, thank you 3. OLC: no comments, thank you 4. IBC: A) wall signs, directional signs - no comments, thank you B) freestanding sign - connection details are required for the pipe to cabinet system C) specify how the lettering on the top cabinet is affixed (i.e. internal mounts for push through or external mounts to cabinet face? high wind should be accommodated) 5. FCC / General Safety: No comments, thank you RESUBMIT ALL DIAGRAMS AND DOCUMENTS IN THIS PACKAGE - AND THE ENGINEERING REQUIRED FOR CONNECTION FROM PIPE TO CABINETRY, AND ANY SPECIAL INSPECTIONS ASSOCIATED. STRUCTURAL REVIEWER WILL COMPLETE THEIR REVIEW AT THAT TIME. I can be reached at Heather.Thrall@tucsonaz.gov |