Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TS-PRM-0223-00169
Parcel: 117121930

Address:
56 E CONGRESS ST

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0223-00169
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/13/2023 Signs REQUIRES RESUBMIT RE: projecting sign review
AT: 56 E Congress / Monica Cafe
Permit: TS-PRM-0223-00169
Date: 2/13/23
Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov)

Codes: Unified Development Code (UDC), 7A Sign Standards, National Electrical Code (NEC 600), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2108.

1. UDC:
A) sign requires a temporary revocable easement to be within the right of way. May be possible to use existing dining TRE. Contact Ryan.Tripp@tucsonaz.gov for assistance and resubmit with their written authority to proceed.

2. NEC / OLC:
A) sign shut off shall be midnight, add note to plan
B) sign shall have UL, manufacturer and installer sticker on it, add note to plan
C) dedicated sign circuit shall be labeled at breaker panel, add note to plan
D) clarify on diagram where shut off switch and power supply is located, provide lock out if on inside of wall

3. IBC:
A) add note on the weight of the sign to evaluate anchors.
B) add note on how the arm of the sign connect to the cabinet - or is it on piece?

Email me if you have any questions. Thank you - Heather.Thrall@tucsonaz.gov