Permit Number: TS-PRM-0126-00024
Parcel: 13213123A

Address:
3450 S KINO PW

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0126-00024
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/11/2026 Commercial Building Standard REQUIRES RESUBMIT ACTIVITY NO. TS-PRM-0126-00024
ADDRESS/PARCEL: (3450 S KINO PW TUCSON, AZ 85713)

Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
1. FOOTING/FOUNDATION
a. Foundation depth is shown as, “PER LOCAL CITY/STATE CODE”.
i. The above is very vague and is not acceptable.
b. Please provide structural calculations and detail drawings generated by an Arizona Licensed Structural Engineer that is sealed/signed/dated by the engineer.
i. The above is required for:
1. Canopy/Menu Board
2. Clearance Bar
2. STRUCTURAL DRAWINGS
a. Provide structural design/drawings for the following:
i. Canopy structure at the menu board.
ii. Clearance Bar
b. NOTE: In most cases, the manufacturer may already have these design and specification documents. It should contain connection details such as the connection at the top of post and the canopy, structural member sizes, welding callout, fasteners used, finishes, etc.
i. Should this exist, please submit.
3. Please resubmit.
01/26/2026 Commercial Electrical Fast REQUIRES RESUBMIT See outdoor lighting review comments.
01/26/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review TS-PRM-0126-00024 (3450 S KINO PW TUCSON, AZ 85713)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Outdoor Lighting Review:


1. Add the following Note to the referenced sheets: “As per the City of Tucson Outdoor Lighting Code the Electronic Message Center as shown on this page shall automatically dim to 200 NITS or less from sunset to sunrise. OLC 501.5.2” .

2. Add the following notes to each Illuminated Sigh sheet:
“As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K, OLC 501.3.2.”

“24 hour programmable timer installed to comply with the COT Outdoor Lighting Code.
The means of controlling the specific “off” curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “
02/10/2026 Signs Standard REQUIRES RESUBMIT Sign Review TS-PRM-0126-000024 3450 S. Kino Pwy. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049.
1) Show location of menu sign and clearance bar on last aproved site plan, not a google map. Site plan also lists signs that are not included in this application. Please remove mention of any signs that are not being included in this sign permit application.
2) All dimensions need to be shown in feet.decimal format not feet or inches.
3) Signage for this site must be approved by Bourn Properties. Please reach our to Noeme Garcia at Ngarcia@bournproperties.com for an approval letter and resubmit with this letter.