Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.2
Permit Number - TS-PRM-0126-00002
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2026 | Commercial Building Standard | APPROVED | |||
| 01/06/2026 | Commercial Electrical Standard | APPROVED | |||
| 01/06/2026 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TS-PRM-0126-00002 (6298 E GRANT RD Unit:UNIT 140 TUCSON, AZ 85712) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Outdoor Lighting Review: 1. Add the following Note to the referenced sheets: “As per the City of Tucson Outdoor Lighting Code, the Electronic Message Center as shown on this page shall automatically dim to 200 NITS or less from sunset to sunrise. OLC 501.5.2”. 2. Add the following notes to each Illuminated Sigh sheet: “24 hour programmable timer installed to comply with the COT Outdoor Lighting Code. The means of controlling the specific “off” curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “ Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 01/26/2026 | Signs Standard | REQUIRES RESUBMIT | Sign Review TS-PRM-0126-00002 6298 E. Grant Rd. #140. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049. 1. Letter from manufacturer must include the unit identifier name/number and include verbiage that states the sign will not interfere with FCC communications. 2. Site plan must show outline of tenant space within building. 3. Sign drawings must include the following exact copy language: ⦁ All signs and power supply components are UL listed. ⦁ All signs shall have UL sticker, manufacturer sticker and installer sticker, located on the exterior of the sign for inspections. ⦁ All dedicated sign circuits shall be labeled. ⦁ A safety lock out shall be provided for all signs where the shut off switch is not directly visible to the sign ⦁ 24 hour programmable timer installed to comply with the COT Outdoor Lighting Code ⦁ As per the City of Tucson Outdoor Lighting Code the internally illuminated sign as shown on this page does not exceed the 4400k color temp. ⦁ No animation or scrolling allowed. ⦁ Image must stay on screen for at least one (1) minute before changing ⦁ As per the City of Tucson Outdoor Lighting Code the Electronic Message Center as shown on this page automatically dims to 200 NITS or less from sunset to sunrise. 4. Sign drawings must show the location of the emergency disconnect switch. |