Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0123-00160
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/09/2023 | Signs | REQUIRES RESUBMIT | RE: sign review For: wall / canopy signs AT: Pilot Truck Stop / 5570 E Travel Plaza Way Permit: TS-PRM-0123-00160 Date: 2/9/23 Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov) Codes: Unified Development Code (UDC), 7A Sign Standards, National Electrical Code (NEC) 600, Tucson - Pima County Outdoor Lighting Code (OLC), and International Building Code (IBC) 2018 I fully acknowledge that the proposed sign types (wall / canopy signs) and the proposed sign area is allowed. The sign area ratio for this location is 4 square feet of sign area for each foot of street frontage, as it 's adjacent to the freeway. The following review comments are to be added to the plans for the permit record. 1. UDC: A) please provide the frontage for the building on the location plan: 148' along Craqycroft and 88' along I-10. B) please provide all dimensions throughout the plans in decimal feet. ( I acknowledge the total sign area for each sign is provided on the sheet.) C) please enlarge the font pertaining to the lighting - it's really hard to read, thanks 2. NEC / OLC: A) please add the following note to each sheet: internally illuminated signs shall not exceed 4400k color temperature (this is our outdoor lighting code) B) please add the following note to each sheet: a timer shall be provided for the signage, though the location is presently at 24/7 operation. Yes, a corporate timer can be utilized, notations would be required on the plans to indicate so. c) please add the following note to each sheet: dedicated sign circuits to be provided and shall be labeled at the breaker panel d) all MET stickers, manufacturer stickers, and installer stickers shall be placed on each sign e) show power supply behind the wall for the wall signs F) show shut off switch locations for each sign, whether canopy or wall sign G) add note to each sheet: lock outs to be provided for all wall signs at the shut off switch 3) IBC: A) please provide the typical number of mounts for the wall signs B) please show the mounts for the power supply boxes, including size / number of mounts C) please show the mounts for the raceway for the canopy signs to the letters AND to the canopy - call out size / number / type D) indicate wall type for the wall sign locations E) the typical mounting and electrical detail is missing for the taco bell canopy sign F) the typical mounting and electrical detail is missing for the taco bell wall sign Please email me at Heather.Thrall@tucsonaz.gov when you have resubmitted, and I'll pull the file for faster review. Thank you! |