Permit Number: TS-PRM-0123-00130
Parcel: 13355230B

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0123-00130
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/19/2023 Signs REQUIRES RESUBMIT RE: wall sign review
for: Walgreens / 1145 S Harrison Rd
Permit: TS-PRM-0123-00130
Date: 01/19/23
Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov)

Codes: Unified Development Code (UD) 7A Sign Standards, National Electrical Code (NEC) 600, Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018.

1. UDC:
A) update the application with correct street
B) sign F is under 35 sqft for a panel and does not need change of copy, remove from permit application ok to leave in sign package
C) sign G is inside the store and is not reviewed for permits, remove from permit application and from permit package
D) box the "Walgreens" to cut off the tail of the "g" - you're going to do many of these plans, know this will help now
E) box the logo and the words Village Medical separately, just note their sign area next to each and then provide cumulative area - you're going to do many of these plans, so it's good to ensure you know you can do this now

2. NEC / OLC:
A) add note to each page of the construction plans: all signs to shut off by midnight curfew via timer
B) add note to each page of the construction plans: signage shall have dedicated circuit that will be labeled at the breaker panel
C) add note to each page of the construction plans: UL sticker, manufacturer sticker, installer sticker shall be on each sign

3) No IBC comments - attachments fine

Resubmit application and plans on the portal under permit TS-PRM-0123-00130.