Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0123-00127
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/23/2023 | Signs | REQUIRES RESUBMIT | RE: monument sign review For: replacement sign AT: 2604 E Speedway / Raising Cane's permit: TS-PRM-0123-00127 Reviewer: H.Thrall (Heather.Thrall@tucsonaz.gov) Date: 01/23/23 Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC) and International Building Code (IBC) 2018. 1. UDC: A) acknowledged it is a replacement sign and sign area is listed on the application at 50 square feet. For the permit record, please provide all dimensions on the elevation view in decimal feet and provide the sign area of each cabinet. Cumulatively, the sign area cannot exceed 50 sqft. B) site plan is fine, thank you - just resubmit with all docs on portal 2. NEC/ OLC: add the following / specify on elevation view: A) specify if digital sign is a master / mirror operation to as to have same display B) specify if each cabinet has a separate shut off switch C) specify if the volts, amps, noted are for just one cabinet or does the info need checking for both cabinets and then noted it is for both? D) add note: all UL, manufacturer and installer stickers to be on sign E) sign shall shut off via timer at midnight curfew or business closure, later is allowed F) dedicated sign circuit shall be provided and labeled at breaker panel G) digital message center shall dim down to a maximum light brightness of 200 Nits from sunset to curfew H) specify manufacturer of digital sign and unit type, and whether full color or monochromatic I) add note digital sign shall comply with FCC communications and not interfere J) maximum rate of message change for digital sign is 1 x per minute, without transitions or forms of animation 3. IBC: A) thank you for detailed construction and engineered plans, just add note on sign elevation view that for construction details, see engineered plan set B) please clarify, engineer does allow for field welding to occur on sheet S.1. note, but sign elevation view indicates no field welds. While I respect that note, can you kindly clarify if you're welding the cabinets and also the top an bottom plates at the shop and bringing the entire sign down for crane install? (which may need a right of way permit to block off traffic) If not, field welding is fine - just fill out the special inspection form and have Jere Murdoch appoint qualified special inspector. If you have questions, email me. Please email when you've resubmitted all documents so I can pull the resubmittal file for faster review. |