Permit Review Detail
Review Status: Approved
Review Details: RIGHT-OF-WAY REVIEW v.1
Permit Number - TR-UTL-1125-01929
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/06/2025 | ROW Engineering Review - Standard | APPROVED | W. Wyoming St is subject to a pavement moratorium. A 2-inch mill and overlay, covering half the width of the roadway, is required. The ROW inspector will confirm the treatment required for pavement restoration at the preconstruction meeting New individual service line connections and individual service line repairs may be made in new pavements without a moratorium patch requirement provided the backfill and pavement repair includes NO native backfill and the pavement area affected is less than 4-ft wide to complete the T-Top Patch Detail. If the width exceeds the 4-ft maximum width, the area of patch must comply with moratorium patch requirements. Where cuts to pavement under moratorium occur due to an emergency, Utilities may follow the non-moratorium pavement repair requirements described above in lieu of the requirements in section 10.3.2. |
||
| 11/05/2025 | Transportation Application Review Express | REVIEW COMPLETED | New Utility (No Existing) |