Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.2
Permit Number - TR-UTL-0924-01728
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2024 | ROW Engineering Review | REQUIRES RESUBMIT | Requires Resubmittal - Traffic Control Plan Design Company & Listed Barricade Company do not match. Traffic Control Design Company and Barricade company providing services need to be the same company. Please provide ATSSA AND ROC Certification information for Straight Arrow Traffic Control Company as well.. Traffic Control Plan Notes: 1) Please orient Plan so North is to the Top or Left of the Page. 2) Provide plan that is Right of Way Specific Layout. 3) Show Sidewalks & Bike lane on plans if applicable. 4) Show Sign spacing, Taper Lengths, Tangent and Buffer Lengths. 5) Provide Work Hours for Arterial Right of Way per City of Tucson Code. 6) An ADA compliant accommodation needs to be provide when ADA crossing exceed 660' from work area. Bike Accommodation will need to be provide with in the closure on Roads with Speed Limit above 30 MPH, If bike lane is to be closed. 7) Show Driveways with Business access signs within works and TC area. Refer to TDC portal permit request Attachments for example of ADA & Bike compliant detour paths. |
||