Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: TR-UTL-0826-01428
Parcel: 138200910

Address:
7017 S 12TH AV

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-UTL-0826-01428
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2026 ROW Engineering Review - Standard REQUIRES RESUBMIT on TCP pg 5of5
1. Fix advanced warning sign spacing. 350' is too much for a 35 urban collector.
2. Provide taper length.
3. Call out bus stop between W Corona and W Marcus. note whether bus stop will remain or be relocated.
08/28/2026 Transportation Application Review Express REVIEW COMPLETED