Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.2
Permit Number - TR-UTL-0725-01076
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2025 | Transportation Application Review Express | PENDING ASSIGNMENT | |||
| 07/08/2025 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | Re-Review- Not enough Clearance for this Split setup prior to Signalized intersection. 245' Taper extends beyond start of Right turn bay. Recommend Starting Taper south of Right turn bay, then split turn bay. Note a buffer space between end of taper and signalized intersection should be provided for full completion of Merge prior to intersection. |