Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-UTL-0623-01813
Parcel: 13316005K

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.3

Permit Number - TR-UTL-0623-01813
Review Name: RIGHT-OF-WAY REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2023 ROW Engineering Review REQUIRES RESUBMIT TR-UTL-0623-01813 (6612 E TANQUE VERDE RD TUCSON, AZ 85715) 3rd Review

Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed.

Site Plan and Construction Plan
1. Utility Admin Manual - Section 9 – Please use the Submittal Requirement for Utility Work to prepare a site plan and construction plan for this project. https://www.tucsonaz.gov/files/sharedassets/public/dtm/documents/linked-documents/city-of-tucson-public-utility-administrative-manual_20230504.pdf
Traffic Control Plan:
1. Transportation Access Management Guidelines Figure 5-12 -Provide 60’ throat length from the curb (for cars turning onto N Camino Serna) before flagger. Please show the dimension on the plan.
2. Utility Admin Manual – Section 9 -Dimension length and width of area to be reserved/used for the work and restrictions.
3. Utility Admin Manual – Section 9 - Depict provisions for pedestrians. If closing the sidewalk, include a sidewalk control plan (See MUTCD Figure 6H-28 for an example. Email me with questions.)
Faffs Riederer
520.837.6647
Faffs.Riederer@tucsonaz.gov

Abbreviations: City of Tucson Code (COTC), Unified Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (P. A. G. SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R).
07/06/2023 Transportation Application Review REVIEW COMPLETED