Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-UTL-0525-00830
Parcel: 10612001A

Address:
1401 W PRINCE RD

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-UTL-0525-00830
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/27/2025 ROW Engineering Review - Standard REQUIRES RESUBMIT Review Note:
Please review setup and provided clearer depiction of the Setup.
1) Should have a buffer between end of taper and work area
2) Sign placement appears that it could be impacting traffic movement
3) Bikes may not share a traffic lane at speed limits above 30 mph, Bike accommodation to be provide within closure behind barricades
4) Review and confirm Pedestrian access not to be effected, Site plans show possible work area impacts to sidewalks..
05/23/2025 Transportation Application Review Express REVIEW COMPLETED