Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-UTL-0523-01481
Parcel: 132180400

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-UTL-0523-01481
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/12/2023 ROW Engineering Review REQUIRES RESUBMIT TR-UTL-0523-01481 (1002 E TENNESSEE ST TUCSON, AZ 85714)

Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed.

Traffic Control Plan:
1. Show lane widths, include bicycle lane.
2. All signs along Park Ave should have 350’ spacing (not 160’).
3. Dimension width of area to be reserved/used for the work and restrictions. Include a site plan view of the work site with approximate work area dimensions.
4. Depict provisions for pedestrians along arterials.
a. If closing the sidewalk, include a sidewalk plan (See MUTCD Figure 6H-28 for an example. Email me with questions.)
b. Pedestrian route must be safe, detectable, and accessible including ramps, detectable surfaces (truncated domes) and a detectable edge with Longitudinal Channeling Devices (LCDs).
5. Depict provisions for bicyclists along arterials.
a. Bike lane closures should be avoided. Prefer narrowing all travel lanes to accommodate a shifted bike lane. (Tucson Complete Streets Design Guide page 4-15)
b. Second option of closing a travel lane to accommodate a shifted bike lane.
6. Show that warning signs will not obstruct sidewalk or bicycle lane.
Faffs Riederer
Faffs.Riederer@tucsonaz.gov
05/08/2023 Transportation Application Review REVIEW COMPLETED