Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TR-UTL-0325-00481
Parcel: 141114610

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-UTL-0325-00481
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/25/2025 ROW Engineering Review - Standard REQUIRES RESUBMIT 1) Provide buffer at the space prior to work area.
2) Provide Bike access accommodation within closure, 3) Posted Speed limit is above 30 MPH. Bikes unable to share travel lane.
4) E Old Vail Rd is has 4' shoulder can work be maintained within Shoulder..
5) Will Sidewalk be effected by Proposed work.
03/25/2025 Transportation Application Review Express REVIEW COMPLETED