Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.2
Permit Number - TR-ROW-1125-01404
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/21/2025 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | Review Comments: - Tucson Blvd is Arterial Right of Way. Requires pedestrian access to be maintained on existing side of Right of Way, an a ADA compliant surface. 1) Traffic control plan required to be Designed and Provided by ATSSA certified barricade company. 2) Pedestrian compliant surface required for Detour route, with definable and detectable edges. Proposed surface shows as Gravel (ADA compliant Wall , ADA compliant plating or hard packeted surface. ) 3) Pedestrian detours not be be placed on Private property. 4) MUTCD requires a minimum 60" protected path for pedestrian movement. |
||
| 11/21/2025 | Transportation Application Review Express | REVIEW COMPLETED |