Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.1
Permit Number - TR-ROW-1123-01339
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2023 | ROW Engineering Review | REQUIRES RESUBMIT | Construction Plan Reference PAG SD 206 for all driveways Reference PAG 200 for sidewalk show existing curb openings with width dimensions, will existing curb cuts be utilized or relocated? If relocated show locations Driveway width 10' is the minimum, 14' is typically used for single use driveway or 20' for joint use driveway, Recommended to show concept for future residential homes showing proposed driveway locations to determine width Show dimension from property line to behind of curb New driveways/curb cuts should show a dimension from Property line to bottom of driveway apron/ curb cut, 5' is the minimum distance Please see comments on construction drawings, PAG Standard Details 200 and 206 have been attached under attachments. |
||
| 11/15/2023 | Transportation Application Review | REVIEW COMPLETED |