Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-ROW-1123-01339
Parcel: 120030970

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-ROW-1123-01339
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2023 ROW Engineering Review REQUIRES RESUBMIT Construction Plan
Reference PAG SD 206 for all driveways
Reference PAG 200 for sidewalk
show existing curb openings with width dimensions, will existing curb cuts be utilized or relocated? If relocated show locations
Driveway width 10' is the minimum, 14' is typically used for single use driveway or 20' for joint use driveway, Recommended to show concept for future residential homes showing proposed driveway locations to determine width
Show dimension from property line to behind of curb
New driveways/curb cuts should show a dimension from Property line to bottom of driveway apron/ curb cut, 5' is the minimum distance
Please see comments on construction drawings, PAG Standard Details 200 and 206 have been attached under attachments.
11/15/2023 Transportation Application Review REVIEW COMPLETED