Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TR-ROW-1123-01316
Parcel: 11713061Q

Address:
401 W ALAMEDA ST

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-ROW-1123-01316
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2023 ROW Engineering Review REQUIRES RESUBMIT 1. A shadow truck is not allowable for the time needed for pot holing. Shadow trucks are used in a "rolling" operation, or short-term up to 45 minutes. Please resubmit a TCP showing lane closures for each pot hole and including and set up changes in lanes.
2. Congress St is under pavement moratorium. Cut and patch pot-holing will require a pavement moratorium patch according the the City of Tucson Public Utility Administrative manual. If however, a core-drill is used for the pot holes, the patch can be done per the MAG specification.
11/07/2023 MITZ District REVIEW COMPLETED
11/02/2023 Transportation Application Review REVIEW COMPLETED