Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-ROW-1025-01290
Parcel: 126120140

Address:
4670 E 5TH ST

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.2

Permit Number - TR-ROW-1025-01290
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2025 ROW Engineering Review - Standard REQUIRES RESUBMIT Review Below comments: Provide Site/Design plan showing and meeting Below standards. Proposed area show Utility Pole and Water Meter.
1) Driveway/ Curb Cut to meet PAG 206 Standards - Concrete from pavement to back of Sidewalk, Maintain Concrete build.
2) Build to meet City of Tucson Chapter 25 code -
Sec. 25-38. Special requirements in residential districts.
(a) Curb cuts and driveways shall conform to the following requirements in all residential zoned districts:
Minimum curb cut width . . . . . 10 feet
Maximum curb cut width . . . . . 20 feet
Maximum curb cut width for 2 adjoining properties . . . . . 30 feet
Minimum distance between curb cuts . . . . . 12 feet
Minimum distance of curb cut from street light standards, or catch basins . . . . . 5 feet
Minimum distance of curb cut from a fire hydrant of city water hydrant . . . . . 20 feet
Minimum distance of curb cut from end of a curb return . . . . . 4 feet
OR
from a curb line or a cross street at a street intersection, whichever is more restrictive . . . . . 20 feet
10/31/2025 Transportation Application Review Express REVIEW COMPLETED