10/18/2023 | ROW Engineering Review | REQUIRES RESUBMIT | The bore path provided shows boring crossing Granada Ave and Congress St. There are numerous utilities in these roadways where these boring crossings are. Please provide a “Detailed” Site Plan showing all BORE PITS and all POT-HOLE locations over utilities. The TCP(s) will need to be revised to show traffic control, lane closures and alternate set-ups as these locations are accessed during the work. REQUIRED, 1. Detailed Site Plan. 2. Bore pit and pot-hole locations shown on plan. 3. TCP(s) showing appropriate traffic control as the bore pits and pot-holes are accessed. A site plan needs to show the “Location of the work” in relation to, 1. The roadway/ street (names) 2. North Arrow 3. Location of Curb/ medians/ SunLink tracks 4. All adjacent vehicle lanes/ correct number of lanes/ BIKE Lanes 5. Location of Sidewalk 6. Existing utilities in the area 7. Show roadway widths/ lane widths. 8. Area and extent of excavation |
||