Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-ROW-0926-01024
Parcel: 14026002K

Address:
2000 E DREXEL RD

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.2

Permit Number - TR-ROW-0926-01024
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2026 Transportation Application Review Express PENDING ASSIGNMENT
10/13/2026 ROW Engineering Review - Standard REQUIRES RESUBMIT DTM Review Notes:
1) Traffic Control plans still uploaded in incorrect orientation.
2) Confirm Sign Spacing. Speed reduction does not Warning reduction in Sign spacing.
Maintain the 350' . MUTCD Table 6B-1 - Spacing should match the 85th percentile of Drivers
3)Note: Plan to Show and Call out Full Project Closure length per setup or setup Phase. - Taper, Buffer, Work area, Return.
4) Where is the Rest of the Detour Route that is being Proposed
5) Plans should include the Full length of the TC closure from 1st VP to Last VP per page or per setup type.
6) Review Hard Closures and associated detour route
7) Please provided additional details regarding the setups - As Noted currently as 24 hr closure for RLC NB Campbell, With Local residentials being up during the week and taken down on weekends?
8) Recommend Reviewing the DTM Web page and the new fee structure for Loss of Use Fees and Loss of Value fees.