Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.3
Permit Number - TR-ROW-0925-01174
Review Name: RIGHT-OF-WAY REVIEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2025 | Transportation Application Review Express | PENDING ASSIGNMENT | |||
| 10/07/2025 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | Permit review notes : Design Plan comments • ADA ramp connection at the corner of Estrella and Grant Rd to be redesigned and rebuilt to safely accommodate pedestrian movement or Sidewalk should be routed to the East for a connection point prior to the existing Ramp location • Southern Most driveway is recommended to be an Entrance only and reduced in size to better accommodate sidewalk build and pedestrian movement • All Driveways should be built to PAG 206 standards with concrete sidewalk being Maintain through the Driveway. • Vertical Curb to be maintained for the full length of the property along Estrella Av. • All sidewalk requires a 3’ Buffer behind back of curb. Traffic Control Plan -- Re-upload Traffic control to match and address Flat work associated with request new design plans from the Contractor.. |