08/28/2025 Transportation Application Review Express PENDING ASSIGNMENT
08/29/2025 ROW Engineering Review - Standard REQUIRES RESUBMIT Revision Notes:
1) Traffic Control plan requires not detail to design. Design should be more proportional.
2)Calling out Shoulder closure but no VPs or shoulder tapers shown or called out on the plan.
3) Show on TC design or as supplement box on plan showing ADA detour layout.
4) Sign spacing for 40mph should be 350'
5) Refer to MUTCD for examples- Chapter 6 Figure 6P-28, and 6K figure 6K-2.
Refer to COT Utility manual Page 41 - 42