Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.5
Permit Number - TR-ROW-0825-01013
Review Name: RIGHT-OF-WAY REVIEW v.5
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2025 | Transportation Application Review Express | PENDING ASSIGNMENT | |||
| 08/29/2025 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | Revision Notes: 1) Traffic Control plan requires not detail to design. Design should be more proportional. 2)Calling out Shoulder closure but no VPs or shoulder tapers shown or called out on the plan. 3) Show on TC design or as supplement box on plan showing ADA detour layout. 4) Sign spacing for 40mph should be 350' 5) Refer to MUTCD for examples- Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |