Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-ROW-0825-01013
Parcel: 113043310

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.3

Permit Number - TR-ROW-0825-01013
Review Name: RIGHT-OF-WAY REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/20/2025 ROW Engineering Review - Standard REQUIRES RESUBMIT Review Plan Comments -
1) Show and provide more accuracy on plans depicting Existing ROW configuration. Show Bike Lane, Side Streets, Driveways, Sidewalk
2)Pedestrian Access & Sidewalk
PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST MARKED ADA ACCESS RAMPS IF LOCATED WITHIN 660' OF CLOSURE. PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED IF NO MARKED ADA RAMPS AND CROSSING ACCESSABLE WITHIN 660' OF SIDEWALK CLOSURE. ACCESSABLE.
Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2.
Refer to COT Utility manual Page 41 - 42
Refer to COT 2015 Addition to the MUTCD section 14
Provide Pedestrian Detour Route
3) Bike Lane Access and Accommodation.. Posted Speeds 30 Mph or More – Any Lane Size - Provide a reasonable alternative for cyclists, such as a paved path, space behind barricades, or bike detour. Acceptable to direct cyclists to the sidewalk when properly signed depending on conditions
4) Driveway and Sidewalk Replacements to MEET PAG 200 & PAG 206 Standards
08/20/2025 Transportation Application Review Express REVIEW COMPLETED