| 07/14/2026 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | DTM Review Comments : Site/Design Plans - 1) Review DTM Chapter 25-38- Driveway Min width is 10' - Max 20' - Meeting PAG 206 Standard detail. 2) Review Technical Standards Manual 10-01.4.3 - Driveway to be full Concrete Construction to back of Sidewalk - 3) Review and Confirm Site Visibility Triangle for Sidewalk and 3rd Street from Garage. Traffic Control Plan --- 1) Review Plan Location call outs do not match the Site and Design Plan Location of work off 3rd Ave |
||
| 07/13/2026 | Historic | REVIEW COMPLETED | Review complete for curb cut in ROW. Note that associated new garage on parcel has previously been through historic review (SD-0825-00129). | ||
| 07/10/2026 | Transportation Application Review Express | REVIEW COMPLETED |