Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.1
Permit Number - TR-ROW-0723-00969
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/26/2023 | ROW Engineering Review | REQUIRES RESUBMIT | Traffic Control Plan There is no turn lane where the work area is located. It is a two lane roadway in the area of the proposed sewer line. Revise TCP. 24 HR TCP setup will not be approved if work is not being performed at night. If work is being performed at night, an approved Temporary Noise Exemption (TNE) from City Manager's office will need to be submitted prior to permit issuance. Sign spacing is incorrect for 45 MPH posted speed limit. |
||
07/20/2023 | Transportation Application Review | REVIEW COMPLETED |