Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.2
Permit Number - TR-ROW-0526-00612
Review Name: RIGHT-OF-WAY REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2026 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | DTM Review Comments: 1) Show clearer depiction of Right of Way - Call out/Show Distance from Edge of Curb to Property Line. 2) Review provided Side Plan - 303 Sf driveway called out on North side of Property with proposed Curb Cut on South end of Property, With Street level photos showing driveway and possible parking area on South End property 3) Per City Chapter 25 - 12' Minimum required to be Maintained between Driveway (Curb Cut) for On property and Neighboring Addresses. 4) Curb Cut/Driveway to meet PAG 206 standard Detail and Technical Standards Manual 10-01.4.3 requiring full concrete driveway construction from edge of pavement to back of sidewalk (Required Pedestrian Clear area) approximately 8' - SHOW AND DEPICT ON PLAN. 5) Planting within City of Tucson Right of Way will require review by DTM Landscaping Engineer. |
||
| 06/08/2026 | Archeological Sensitivity - Standard | REVIEW COMPLETED | waiver issued | ||
| 06/08/2026 | Transportation Application Review Express | REVIEW COMPLETED |