Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.1
Permit Number - TR-ROW-0524-00573
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/20/2024 | Historic | REQUIRES RESUBMIT | The proposed work plan is not clear. It appears that the landscaping strip is proposed for concrete, please clarify. The historic sidewalk is composed of 3 equal scored squares that should be replicated with the replacement concrete. Please clarify on the site plan. Additionally, any extant sidewalk stamps should be noted on the plans and should be preserved. The stamps should be saw cut out in one piece, stored in a safe place, and re-installed in or near their original location with the same orientation. Provide information, on how deep the soil will need to be disturbed to install the new sidewalk. Questions? Jodie.Brown@tucsonaz.gov |
||
05/15/2024 | ROW Engineering Review | REQUIRES RESUBMIT | Site plan: Entire width of sidewalk should be replaced to bring up to standard, see PAG SD 200; if existing 2'x2' pattern is proposed, label "modified" to PAG SD 200 with additional detail of pattern. *New construction in the public Right-of-Way shall be in conformance with the current edition of Pima Association of Governments (PAG) Standard Specifications and Details for public improvements. Visit https://apps.pagregion.com/standardspecifications/ for PAG standards and specifications. DTM site plan comment file, and PAG Standard Detail 200 have been added in attachments. |
||
05/14/2024 | Transportation Application Review | REVIEW COMPLETED |